9 Dimensional WSS Board in DCI Box

9 Dimensional WSS Board in DCI Box
Details:
9-dimensional WSS board of DCI Box
Send Inquiry
Description
Send Inquiry

9-dimensional WSS board

 

1) The schematic diagram of the internal structure of the WSS board is shown in the picture 1, and the board occupies 1/2 slot. required built-in BA and PA, built-in VOA before PA input; OCM, OTDR built-in optional.

 

2) The gain range of BA is 15~25dB; the gain of PA1 covers at least 15~25dB, and the gain of PA2 covers at least 22~35dB. For the performance requirements of BA and PA.

 

3) For power monitoring points, see the position of the PD icon in picture 2 of the internal structure diagram of the board; the output calibration value of BA is calibrated to the LINE OUT port; the input side of PA reports two input power values.

 

The input calibration value of the VOA is calibrated to the LINE IN port, and the input calibration value of the EDFA is the measured value at the LINE IN port minus the attenuation value of the VOA and the coupling insertion loss between the receiving side of the OSC and the main optical path. The input scaling of BA and the output scaling of PA are to be determined.

 

4) The board provides two indicator lights, at least three colors of red, yellow, and green. The indicator STAT is used to indicate the running status of the board, and the indicator LINE is used to indicate the status of the optical port of the corresponding port.

product-652-309

1 Schematic diagram of the internal structure of the 9-dimensional WSS board

 

 

WSS Module Specifications

Project

Unit

Idex

Note

Channel Spectral Width

GHz

N*12.5GHz

4≤N≤12

Wide tuning range of signal spectrum

Nm

1528.773~1566.73

 

Insertion Loss(Add1~9 to BA In)

dB

≤7.5 (typical value)

 

Insertion Loss (PA Out to Drop1~9)

dB

≤7.5 (typical value)

 

The maximum difference in insertion loss of each channel

dB

≤2.5

 

Port isolation

dB

>25

 

Extinction Ratio

dB

≥25

 

polarization dependent loss

dB

≤1.5

 

Attenuation range per wavelength

dB

0~15

 

Decay setting step size

dB

0.2

 

Attenuation accuracy per wavelength

dB

≤1

(0~10dB)

≤1.5

( > 10dB)

refactoring time

s

≤3

 

1dB minimum spectral width

GHz

>50

@100GHz spectral width

3dB minimum spectral width

GHz

>75

@100GHz spectral width

20dB minimum spectral width

GHz

<150

@100GHz spectral width

Mon split ratio

dB

16~23

Split ratio 1%~2%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

 

Hot Tags: 9 dimensional wss board in dci box, China, manufacturers, suppliers, factory, customized, buy, price, bulk, compatible brand, Optical Add Drop Multiplexer Card, NMS Card, 9 Dimensional WSS Board in DCI Box