How to judge the fault of the Fiber Converter? .

Jun 22, 2020

Leave a message

How to judge whether there is a problem with the optical fiber transceiver?


(1) First, see if the indicator light of the optical fiber transceiver or optical module and the indicator light of the twisted pair port are on

 

a. If the FX indicator of the transceiver is off, please confirm whether the fiber link is cross-linked? One end of the fiber jumper is connected in parallel mode; the other end is connected in cross mode.

 

b. If the optical port (FX) indicator of the A transceiver is on and the optical port (FX) indicator of the B transceiver is off, the fault is on the A transceiver side: one possibility is: A transceiver (TX) optical transmission The port is broken because the optical port (RX) of the B transceiver does not receive the optical signal


c. c. The twisted pair (TP) indicator is not on. Please make sure that the twisted pair connection is wrong or the connection is wrong? Please use a continuity tester to test (however, the twisted pair indicator lights of some transceivers must wait until the fiber link is connected).


d. Some transceivers have two RJ45 ports: (ToHUB) indicates that the connection line to the switch is a straight-through line; (ToNode) indicates that the connection line to the switch is a crossover line.

e. Some hair extensions have an MPR switch on the side: it means that the connecting line to the switch is a straight-through method; DTE switch: the connecting line to the switch is a cross-over method.


(1) Confirm whether the optical cable or optical fiber jumper is broken

a. Optical cable connection and disconnection detection: use laser flashlight, sunlight, luminous body to illuminate one end of the optical cable connector or coupling; see if there is visible light at the other end? If there is visible light, it indicates that the optical cable is not broken.


b. On-off detection of optical fiber connection: use laser flashlight, sunlight, etc. to illuminate one end of the fiber jumper; see if there is visible light on the other end? If there is visible light, the fiber jumper is not broken.


c. Whether the half/full duplex mode is wrong.


Some transceivers have FDX switches on the side: full duplex; HDX switches: half duplex.

 

(4) Test with optical power meter


The luminous power of the optical fiber transceiver or optical module under normal conditions: multi-mode: between -10db--18db; single-mode 20 kilometers: -8db--15db; single-mode 60 kilometers: -5db--12db ; If the luminous power of the fiber optic transceiver is between -30db and -45db, then it can be judged that there is a problem with this fiber optic transceiver.


收发器

Send Inquiry